• Open
  • Muhammad Idris
    Participant
      October 10, 2007 at 9:23 am #2906
      Avatar photo

      Flat post tension slab (parking, 8 x 6.5m) long side 96 meters,
      Anyone please advise for pour strip location and detailing.

      IjazzGul
      Participant
      Posts: 20
        May 3, 2008 at 7:08 am #3173

        pour strip location is 800mm away to retaining wall and additional rienforcement to pour strip conection.

        Administrator
        Keymaster
        Posts: 66
          May 4, 2008 at 7:28 pm #3174
          Avatar photo

          divide the slab into two pours by 48 meters or something close, pout strip locate in quarter span (zero moment)
          e.g. if 8 m span locate it 2 m away from one column
          if 6.5 m then 1.5 m from one of the columns.
          detailing:
          top and bottom bars ovrlapping …you know that
          :)

          Decipher
          Participant
          Posts: 46
            August 1, 2008 at 2:59 pm #3181
            Avatar photo

            pourstrip must be located at zero moment which is located more or less 1/3 of the span